Products

List of all the Products
MG2025

Frequency: 2993-3002 MHz
Peak Power: 2600 kW

MG2025

Frequency: 2993-3002 MHz
Peak Power: 2000 kW

MG2025

Frequency: 2993-3002 MHz
Peak Power: 2000 kW

MG2025

Frequency: 2993-3002 MHz
Peak Power: 2000 kW

MG2025

Frequency: 2992-3001 MHz
Peak Power: 2600 kW

MG6028

Frequency: 2852-2861 MHz
Peak Power: 5500 kW

MG6090

Frequency: 2993-3002 MHz
Peak Power: 3100 kW

MG6363

Frequency: 2852-2861 MHz
Peak Power: 5500 kW

MG7095

Frequency: 2993 – 3002 MHz
Peak Power: 3100 kW

MG8076

Frequency: 2998 MHz
Peak Power: 7500 kW

MG6062

Water Cooled electromagnet
Used with: MG5193, MG5125, MG5125P

MG6053

Water cooled electromagnet
Used with: MG5349, MG6090

MG6030

Water cooled electromagnet
Used with: M5028, MG6028

M4152S

Waveguide Transition
Used with: MG5193, MG5125, MG5125P

MG6405

Water cooled electromagnet
Used with: MG6493

MA997A

Capacitor
Used with: M5028, MG6028

MA6191

Filament Lead Varian

MA6291

Filament Lead Siemens

CX1154

Peak Anode Voltage: 40 kV
Peak Current: 3 kA

CX1154L

Peak Anode Voltage: 35 kV
Peak Current: 3 kA

CX1180

Peak Anode Voltage: 25 kV
Peak Current: 1 kA

8503K

Replacement for the 8503AG
Peak Anode Voltage: 20 kV

8503C

Replacement of the 8503B
Peak Anode Voltage: 20 kV

CX1140

Peak Anode Voltage: 25 kV
Peak Current: 1 kA

CX1140A

Peak Anode Voltage: 25 kV
Peak Current: 1 kA

CX1140LG

Replacement of the CX1140LE
Peak Anode Voltage: 33 kV

CX1159G

Replacement of the CX1159
Peak Anode Voltage: 33 kV

CX1191D

Peak Anode Voltage: 16 kV
Peak Current: 0.4 kA

CX1559

Peak Anode Voltage: 35 kV
Peak Current: 1.5 kA

CX1551

Peak Anode Voltage: 33 kV
Peak Current: 1 kA

MG2025

Peak Anode Voltage: 35 kV
Peak Current: 5 kA

MA91

Used with: CX1140, CX1140A, CX1140LE, CX1159

MA92

Used with: CX1140, CX1140A, CX1140LE, CX1159

MA94

Used with: CX1140, CX1140A, CX1140LE, CX1159

MA153

Used with: CX1140, CX1140A, CX1140LE, CX1159

MA179

Used with: CX1140, CX1140A, CX1140LE, CX1159

MA357

Used with: 8503B, 8503AG, CX1191D

MA357A

Used with: 8503B, 8503AG, CX1191D

MA359

Used With: 8503B, 8503AG, CX1191D

MA360A

Used with: CX1140, CX1140A, CX1140LE, CX1159, CX1191D

MPT5838 (AMM1)

The MPT Series is a range of fully integrated, compact, direct switching, high voltage solid-

MPT5839 (AMM2)

The MPT Series is a range of fully integrated, compact, direct switching, high voltage solid-

Elekta

Various OEM spare parts used in Elekta linear accelerators.

Varian

Various OEM spare parts used in Varian linear accelerators.

Elekta

Marine magnetrons from 1.5 – 25 KW at a frequency range between 9345 – 9680 MHz.

Elekta

Marine magnetrons from 10 – 60 KW at a frequency range between 3010 – 3090 MHz.

Elekta

Magnetrons for Coastal Surveillance radars, Vessel Traffic Systems and Ground Movement radars on..

Elekta

Compatible marine magnetrons from 4 – 10 kW at a frequency between 9380 – 9440 MHz.

e2v technologies manufacture Ferrite Devices operation from 350 MHz to 120 GHz, for a wide variety of applications from low cost marine radar to state-of-the-art military devices. Standard units are available in regular waveguide sizes and some special sizes.
e2v technologies offer circulators and isolators as stand-alone units and also as part of an integrated microwave package. They all come with the assurance that e2v technologies have facilities to power test units, giving confidence in all devices.

Guide your signal to transmitter or antenna

You can use the circulator to prevent a mix-up of the signals. The operation of a circulator can be compared to a revolving door with three entrances and one mandatory rotating sense. A microwave signal entering via one specific entrance follows the prescribed rotating sense and has to leave the circulator via the next exit. If an antenna is in a connection, transmitting energy is always escorted to the antenna while the echo signals always find the way to the receiver.

X-Band Circulators

X-Band circulators

S-Band Circulators

S-Band circulators

e2v technologies manufacture a broad range of receiver protectors in all radar frequency bands from 1.25 to 40 GHz. The high power waveguide devices specified below are divided into two categories:

  1. Solid state receiver protectors that normally require synchronous bias during transmission; additional passive protection can often be included
  2. Passive limiters that require no external bias

Extra options for your limiter

PIN switches can be supplied:
  • with or without electronic drive circuit
  • with drive circuit and built-in test (BIT)
  • with quasi-active circuits fot interpulse protection
  • with pre-TR tubes for high peak power fault conditions
  • with phase and amplitude matching
All solid-state receiver protectors can be supplied with the following options:
  • additional filtering >to attenuate spurious transmissions or extend protection range
  • precision dynamic attenuation (STC), digital or analogue
  • solid-state noise generators for inter-pulse performance monitoring

X-Band Circulators

X-Band limiters

S-Band Circulators

S-Band Limiters

Use a front-end as a radar component and you can receive S- and X-band frequencies ranges with one application.

Efficiency in use of the EEV radar system

e2v technologies Ltd. developed these components to make it posssible to receive signals from both the S- and X-band frequency ranges, instead only one of them.

X-Band Front Ends

X-Band Front Ends

S-Band Front Ends

S-Band Front Ends